Hot shot 2 p t chart - Hot Shot® almost exactly duplicates the operating characteristics of R-12. Use it for low, medium, and high temperatures. Use it in autos, aircraft, and boats. Use it in air-conditioning and refrigeration systems—anywhere you used to use R-12. With Hot Shot®, there is simply no need to inventory multiple gasses. No systems modifications ...

 
™ Hot Shot-2 Refrigerant (R-417C) Product Information Freon™ Hot Shot-2 (R-417C) is a non-ozone depleting A1 refrigerant that can be used as a direct replacement into existing systems that are still operating with R-12, R-134a, or R-500. Freon™ Hot Shot-2 is compatible with traditional and new lubricants; in most cases, no change of .... What time does church

*Computer simulation per manufacturer's published component percentages Italicized amounts = Inches of mercury below one atmosphere BP=Boiling point, DP=Dew point Pressure = PSIG Convenient and easy-to-use. One advantage to retrofitting to Hot Shot 2 is that you do not need to perform a costly and time consuming compressor oil change. Hot Shot 2 is compatible with all compressor oils. Hot Shot 2 Facts: • Zero Ozone Depletion Potential • Non Toxic and Non Flammable • Compatible with all compressor oilsTwenty years ago, ICOR International, Inc., a relatively unknown refrigerant producer and reclaim company from Indianapolis, Indiana , introduced HOT SHOT® (R-414B).At the time, there were three ...Our selection of vibrate One Shot paint colors includes purple, sublime green, lemon yellow, polar white, metallic silver, imitation gold and more than two dozen other colors. Add One Shot hardener to help the paint dry faster, Chroma 6000 Flow Enhancer to improve leveling or a temperature-adjusted thinner to increase spread. Pinstriping ... A Cost-Effective R-22 Retrofit Refrigerant for AC and Refrigeration. Freon™ MO59 (R-417A) refrigerant is a hydrofluorocarbon (HFC) retrofit alternative for R-22 in direct expansion (DX) stationary air conditioning (AC) and medium-temperature commercial refrigeration systems. Because Freon™ MO59 is compatible with mineral (MO), alkylbenzene ...Use Hot Shot 2 P/T chart on reverse side. If additional Hot Shot 2 needs to be added, do so in 5% increments and DO NOT exceed 115% of the original charge of R-12. If system perfor FRIGERANTS-Conversion Recommendations And Procedures mance is inadequate, call ICOR for support at 800-497-6805. Sad as it is, Giannis cannot dunk the ball on every possession, despite his unassailable (100.0%) conversion rate. The low-percentage shots are often easier to find than the high-percentage shots.P°.ressure control settings assume a suction line pressure loss equivalent to 2 F CARRYING CAPACITY OF REFRIGERATION LINES Tons of Refrigeration - 200 Feet Equivalent Pipe Length TYPE L COPPER TUBE O.D. Inches REFRIGERANT IRON PIPE SIZE Inches SCHEDULE REFRIGERANT 2a2 173 44)A/ 50 17 ( m onia L q u id Line S ct on 2° .0 F0Evap 2° .F0Evap ...A1 2.5 MINERAL OIL or ALKYLBENZENE Has been used successfully in 13B1 type equipment. Low-Medium Temperature Refrigeration (R-502 Type) R-22 100 A1 0 MINERAL OIL or ALKYLBENZENE Equipment typically uses liquid injection cooling (high dis. T) R-402A 125/290/22 (60/2/38) A1 2.5 ALKYLBENZENE OR MO/AB MIX Retrofit blend; higher discharge pressure ...Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!STANDARDS FOR INTERAGENCY HOTSHOT CREW OPERATIONS . NATIONAL INTERAGENCY FIRE CENTER 3833 S. Development Avenue Boise, Idaho 83705-5354 . January 21, 2016 STANDARDS FOR INTERAGENCY HOTSHOT CREW OPERATIONS . NATIONAL INTERAGENCY FIRE CENTER 3833 S. Development Avenue Boise, Idaho 83705-5354 . January 21, 2016PT Chart Index. Select by ASHRAE Name. Select by Trade Name. R-11. Alaskan Cool R-176. R-12. Allied Signal AZ50. R-13. Apr 16, 2015 · Twenty years ago, ICOR International, Inc., a relatively unknown refrigerant producer and reclaim company from Indianapolis, Indiana , introduced HOT SHOT® (R-414B).At the time, there were three ... Gallery of online chart tool reviews pricing and alternative. pinterest.ru Pin on Guns. thedailyshot.com Higher prices offset rate-driven gains in US housing afforda. playground.ru PlayGround.ru. townofcarywis.org skew t chart explained - Fomo. gfecc.org Gallery of if you shot a gun in a zero gravity but normal at. lindatyoung.github.io ...So, let’s use $2.25 as an example to figure out typical hot shot trucking rates. If you take 67% of $2.25, you are at about $1.50. If you take 75% of $2.25, you are at about $1.69. So the ballpark for hot shot trucking rates per mile should be anywhere from $1.50 to $1.69, before factoring in the other variables.PT Chart Index. Select by ASHRAE Name. Select by Trade Name. R-11. Alaskan Cool R-176. R-12. Allied Signal AZ50. R-13. Hot Shot® almost exactly duplicates the operating characteristics of R-12. Use it for low, medium, and high temperatures. Use it in autos, aircraft, and boats. Use it in air-conditioning and refrigeration systems—anywhere you used to use R-12. With Hot Shot®, there is simply no need to inventory multiple gasses. No systems modifications ... Most a are White, with 75.2% of Hot Shots belonging to this ethnicity. 11.1% of Hot Shots are Hispanic or Latino, 6.1% of Hot Shots are Black or African American, 4.9% of Hot Shots are Unknown, 1.7% of Hot Shots are Asian, and 1.0% of Hot Shots are American Indian and Alaska Native.rs-24 pressure/temperature comparison values shown: hg" and psig *denotes hg" r-12 r-134a rs-24 rs-24 r-414b r-414b liquid vapor liquid vapor temperature bubble pt. dew pt.It facilitates easy retrofitting in which the technician simply recovers the R-22, replaces critical seals, charges the Freon™ MO99™ refrigerant, and monitors for leaks. Converting to Freon™ MO99™ also: Minimizes time needed for adjustments and subsequent service calls. Doesn't require an expansion valve or line set changes.Apr 10, 2023 · 2. What are the active ingredients and what is the percentage of each active ingredient on each pesticide? Hot Shot Fogger: Tetramethrin 0.10%, Cypermethrin 0.60%, Other ingredients 99.30%. Hot Shot No‐Mess Fogger: Tetramethrin 0.20%, Cypermethrin 0.86%, Piperonyl butoxide 0.50%, Other Ingredients 98.44%. Use indoors, outdoors or anywhere ants are a problem to kill the queen and destroy the colony. These child-resistant bait stations start killing in hours and continue killing up to 6 months indoors. Use near walls, in closets and cabinets and under sinks and refrigerators. Just place one bait station along each ant trail. Twenty years ago, ICOR International, Inc., a relatively unknown refrigerant producer and reclaim company from Indianapolis, Indiana , introduced HOT SHOT® (R-414B).At the time, there were three ...™ Hot Shot-2 Refrigerant (R-417C) Product Information Freon™ Hot Shot-2 (R-417C) is a non-ozone depleting A1 refrigerant that can be used as a direct replacement into existing systems that are still operating with R-12, R-134a, or R-500. Freon™ Hot Shot-2 is compatible with traditional and new lubricants; in most cases, no change of ...Title: Temperature - Pressure Chart for R-22, R-410A, R-407C, R-134A and R-404A Refrigerants Author: Advantage Engineering, Inc Created Date: 10/10/2012 3:31:12 PMTwenty years ago, ICOR International, Inc., a relatively unknown refrigerant producer and reclaim company from Indianapolis, Indiana , introduced HOT SHOT® (R-414B).At the time, there were three ...Convenient and easy-to-use. One advantage to retrofitting to Hot Shot 2 is that you do not need to perform a costly and time consuming compressor oil change. Hot Shot 2 is compatible with all compressor oils. Hot Shot 2 Facts: • Zero Ozone Depletion Potential • Non Toxic and Non Flammable • Compatible with all compressor oils The original Hot Shot is 414b, there is also a Hot Shot 2 on the market. Hot Shot is a drop-in for R12, and Icor also says you can use it in place of 134a, and a few others. I believe its compatible with all oils (mineral, ab, poe) Mixing refrigerants is bad, I don't recommend it. We use Hot Shot for medium temp coolers and have had good results.Preheating: Heat at a rate not exceeding 400°F per hour (222°C per hour) to 1200-1300°F (649- 704°C) and equalize. Austenitizing (High Heat): Heat slowly from the preheat to 1475-1500°F (802-816C) Soak for 30 minutes for the first inch (25.4 mm) of thickness, plus 15 minutes for each additional inch (25.4 mm).HOT SHOT 2™ (R-417C) Version 2.0 Revision Date: 10/25/2018 SDS Number: 2770442-00002 Date of last issue: 05/07/2018 Date of first issue: 05/07/2018 4 / 16 Handle in accordance with good industrial hygiene and safety practice, based on the results of the workplace exposure assessment Wear cold insulating gloves/ face shield/ eye protection.An R-12 Retrofit Refrigerant for Stationary AC and Refrigeration Systems. Freon™ MP39 (R-401A) refrigerant is a hydrochlorofluorocarbon (HCFC) retrofit option for R-12 in stationary positive displacement air conditioning (AC) and refrigeration systems that are used mainly in retail food refrigeration applications.A Cost-Effective R-22 Retrofit Refrigerant for AC and Refrigeration. Freon™ MO59 (R-417A) refrigerant is a hydrofluorocarbon (HFC) retrofit alternative for R-22 in direct expansion (DX) stationary air conditioning (AC) and medium-temperature commercial refrigeration systems. Because Freon™ MO59 is compatible with mineral (MO), alkylbenzene ... Two-column PT charts are every bit as useful as the traditional ones. The charging and service procedures are very similar for both single-component refrigerants and zeotropic blends, and the specialized liquid and vapor data correct for the effects of the blends' temperature glide.Jan 21, 2013 · It would be rare indeed to find service technicians who could not put their hands on a pressure-temperature (P-T) card at a minute’s notice. In spite of the widespread availability and apparent reference to the pressure-temperature relationship, very few service technicians seem to use the P-T chart properly in diagnosing service problems. Freon One Shot™ C (R-422C) refrigerant is a hydrofluorocarbon (HFC) option that replaces many chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants, including R-22 in low- and medium-temperature applications. Designated ASHRAE A1, Freon One Shot-C™ can be used in systems that currently use: R-402A. R-402B. R-404A. R-408A ...Freon™ 95 is a perfluorocarbon (PFC) based azeotropic blend comprised of R-23 and R-116 refrigerants. Benefits include: An ASHRAE A1 classification. A significantly lower compressor discharge temperature vs. R-23, ensuring optimum system reliability for critical applications. 30% greater cooling capacity than R-13 and comparable performance ...Use Hot Shot 2 P/T chart on reverse side. If additional Hot Shot 2 needs to be added, do so in 5% increments and DO NOT exceed 115% of the original charge of R-12. If system perfor-mance is inadequate, call ICOR for support at 800-497-6805. 9) PROPERLY LABEL SYSTEM: Avoid mixing refrigerants by properly labeling your system. For Hot Shot 2 ... Gallery of online chart tool reviews pricing and alternative. pinterest.ru Pin on Guns. thedailyshot.com Higher prices offset rate-driven gains in US housing afforda. playground.ru PlayGround.ru. townofcarywis.org skew t chart explained - Fomo. gfecc.org Gallery of if you shot a gun in a zero gravity but normal at. lindatyoung.github.io ...An R-12 Retrofit Refrigerant for Stationary AC and Refrigeration Systems. Freon™ MP39 (R-401A) refrigerant is a hydrochlorofluorocarbon (HCFC) retrofit option for R-12 in stationary positive displacement air conditioning (AC) and refrigeration systems that are used mainly in retail food refrigeration applications.Freon™ HCFC refrigerants are available for servicing existing equipment in residential and commercial air conditioning and for medium- and low-temperature refrigeration applications. Freon™ 22 (R-22) Refrigerant. Freon™ 123 (R-123) Refrigerant. Freon™ 124 (R-124) Refrigerant. Freon™ MP39 (R-401A) Refrigerant. vapor temperature chart bg-4/14-2.5m. vapor temperature chart. r409a temp. liquid vapor. ... 135 57.2 317 365 329 507 140 60.0 337 389 353 539 145 62.8 359 - - 573 ...Manufacturer part number: HU2HS. $88.01. Overview. Reviews. Contact Us. The HS2000 battery-powered electric livestock prod excels in all conditions, especially on wet animals. Also available in a rechargeable model ( MMCHU2HSR ). Replacement for previous Hog Slat part number: 50430. Handle only. An R-502 Replacement for Limited Condensing Capacity Systems. Freon™ 408A (R-408A) refrigerant is a hydrochlorofluorocarbon (HCFC) option designed to replace the hydrofluorocarbon (HFC) refrigerant R-502. Older systems with limited condensing capacity, and low- or medium-temperature commercial refrigeration systems used in supermarkets often ... R-417C-25LB HOT SHOT 2,,Refrigerants,r417c, r-417c, refrigerant, refrigerants, hot shot 2, hot shot, hotshot 2, hotshot freon,HOT SHOT 2 / 25 LB CYLINDER,Meier Supply ... Some of the zeotropic blends have very low glide (from 1˚F to 2.5˚F). For these blends, the vapor and liquid pressures are only separated by 1 or 2 psi. Because the difference is quite small between the two values some manufacturers’ PT charts will only list one column for these blends. Blends with higher glide (greater than 5˚F will ...In this HVAC Training Video, I Explain Step By Step How to Read the Pressure/Temperature P/T Chart, How to Read the Saturated Temperature of a Refrigerant, H...March 11, 2002 A pocket card called “Pressure Temperature Chart” is available from the company. This foldable, pocket-size card contains a saturation chart that provides data on psig vs. temperature. Another chart has data for coil temperature and the company’s Hot Shot and NU-22 refrigerants.Pressure Temperature Charts Vapor Pressure in PSIG In Vacuum (inches in Hg) °F °C R-417C Liquid R-417C Vapor 60 15.6 73.4 66.7 65 18.3 81.1 74.1 70 21.1 89.3 82.0 75 23.9 98.0 90.4 80 26.7 107 99.3 85 29.4 117 109 90 32.2 127 119 95 35.0 138 130 100 37.8 150 141 105 40.6 162 153 110 43.3 175 166 115 46.1 189 179 120 48.9 203 193 125 51.7 218 ... A Versatile Replacement for Common R-12 Service Blends. Freon™ MO49Plus (R-437A) refrigerant was created as a hydrofluorocarbon (HFC) retrofit for service blends like R-101A, R-401B, and R-409A that contain hydrochlorofluorocarbon (HCFC) components. Freon™ MO49Plus provides a quick, cost-effective way to retrofit existing R-12 and R-500 ... Freon™ refrigerants include a wide range of hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants. The Freon™ portfolio includes products with different thermodynamic and cooling properties to meet application needs. Stationary air conditioning (AC), mobile AC, heat pumps, and domestic and industrial refrigeration systems ...Freon™ NU-22B™ has an ASHRAE A1 classification and is non-ozone depleting and nonflammable. It is well-suited for AC applications because it closely mimics the operating characteristics of R-22 and works over the same operating pressures as R-22. While all mainstream R-22 replacements earn lower capacity ratings, systems that convert to ...Freon™ HP80 (R-402A) refrigerant is used in existing low- and medium-temperature commercial refrigeration systems, including reach-in and walk-in freezers, and supermarket cooling equipment. Freon™ HP80 is a hydrochlorofluorocarbon (HCFC) blend with a small amount of hydrocarbon included to improve compatibility with mineral oil (MO).An R-502 Replacement for Limited Condensing Capacity Systems. Freon™ 408A (R-408A) refrigerant is a hydrochlorofluorocarbon (HCFC) option designed to replace the hydrofluorocarbon (HFC) refrigerant R-502. Older systems with limited condensing capacity, and low- or medium-temperature commercial refrigeration systems used in supermarkets often ... An R-502 Alternative Refrigerant for Low-Temperature Systems. Freon™ HP81 (R-402B) refrigerant is a hydrochlorofluorocarbon (HCFC) retrofit option that acts as a dependable, nonflammable alternative to R-502. Used in limited low-temperature refrigeration applications, this retrofit refrigerant has an ASHRAE A1 safety classification.The number of pellets in each shell will vary depending on the size of the shot and the length of the shell. 2¾-inch #00 buckshot comes with either 8 or 9 pellets. Occasionally you’ll see a 12-pellet load. #1 buck usually has 12 to 16 pellets. #4 will have around 21 to 28 pellets.Freon™ HCFC refrigerants are available for servicing existing equipment in residential and commercial air conditioning and for medium- and low-temperature refrigeration applications. Freon™ 22 (R-22) Refrigerant. Freon™ 123 (R-123) Refrigerant. Freon™ 124 (R-124) Refrigerant. Freon™ MP39 (R-401A) Refrigerant.A Versatile Replacement for Common R-12 Service Blends. Freon™ MO49Plus (R-437A) refrigerant was created as a hydrofluorocarbon (HFC) retrofit for service blends like R-101A, R-401B, and R-409A that contain hydrochlorofluorocarbon (HCFC) components. Freon™ MO49Plus provides a quick, cost-effective way to retrofit existing R-12 and R-500 ..."Hot Shot 2 System Conversion" focuses on the proper procedures to convert existing R-12, R-134a and R-500 systems to ICOR's Ozone safe refrigerant, Hot Shot 2.PT Chart Index. Charts use °F and psig. SI Charts are available for SI Boards. Colours show AHRI GUIDELINE N-1995. refrigerant container colour assignment. AHRI is now specifing that all refrigerant containers should. have one uniform paint color, grey RAL 7044 and that the previously assigned colors should be transitioned.PT Chart Index. Select by ASHRAE Name. Select by Trade Name. R-11. Alaskan Cool R-176. R-12. Allied Signal AZ50. R-13. When that happens, the refrigerant remains at its saturation point. At saturation, you can use the P-T relationship to predict temperature or pressure. P-T charts. The P-T chart is a vital yet often overlooked tool. P-T charts use the pressure-temperature relationship to help you determine the refrigerant’s pressure at a given saturation ...When that happens, the refrigerant remains at its saturation point. At saturation, you can use the P-T relationship to predict temperature or pressure. P-T charts. The P-T chart is a vital yet often overlooked tool. P-T charts use the pressure-temperature relationship to help you determine the refrigerant’s pressure at a given saturation ...Freon™ 507 refrigerant is an azeotropic mixture of R-125 and R-143a with zero ozone depletion potential (ODP). It is a safe, effective alternative to some chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants, including R-502. This hydrofluorocarbon (HFC) has similar qualities to R-502 and performs well in commercial ...PJ Trailers is known for building premium gooseneck trailers for the hotshot industry. Hot shot truckers have increased needs for reliability, durability, comfort, and versatility. We created a guide for customers designing their next hot shot trailer that outlines the most popular specifications & options. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Advantage assumes no responsibililty or liabilitly for data errors. For more information on refrigerant temperatures and pressures call the Advantage Service Department at 317-887-0729. Download the PDF document.Home > Refrigerants > Freon Refrigerant 'Hot Shot 2' 25lb. Jug - R12, R134A, R500, R401A/B, R409A, R414B, R416A, R420A, R426A, R437 & R414A Replacement Freon™ HP80 (R-402A) refrigerant is used in existing low- and medium-temperature commercial refrigeration systems, including reach-in and walk-in freezers, and supermarket cooling equipment. Freon™ HP80 is a hydrochlorofluorocarbon (HCFC) blend with a small amount of hydrocarbon included to improve compatibility with mineral oil (MO).R-417C-25LB HOT SHOT 2,,Refrigerants,r417c, r-417c, refrigerant, refrigerants, hot shot 2, hot shot, hotshot 2, hotshot freon,HOT SHOT 2 / 25 LB CYLINDER,Meier Supply ...™ Hot Shot-2 Refrigerant (R-417C) Product Information Freon™ Hot Shot-2 (R-417C) is a non-ozone depleting A1 refrigerant that can be used as a direct replacement into existing systems that are still operating with R-12, R-134a, or R-500. Freon™ Hot Shot-2 is compatible with traditional and new lubricants; in most cases, no change of ...RS-24 is a non flammable blend of HFC 134a, HFC 125, butane and isopentane which has a zero ODP and is also compatible with both traditional and synthetic lubricants so that a retrofit is not required. RS-24 is a “Drop-in” alternative for R12 which also provides a long term solution at the same time. It provides, therefore, a one change ...Twenty years ago, ICOR International, Inc., a relatively unknown refrigerant producer and reclaim company from Indianapolis, Indiana , introduced HOT SHOT® (R-414B).At the time, there were three ...HOTSHOT REFRIGERANT R414B Product Details HotShot Refrigerant R-414B 25 Lb Cylinder - Direct Replacement For R-12, R-134A And R-500 - Does Not Require Oil Change Or Mixing -Does Not Require Component Change - Compatible With Mineral, R-22 Replacements Pressure-Temperature Guide Key: Green (in of Hg) = Vacuum Black (psig) = Saturated Vapor (calculate Superheat) Bold (psig) = Saturated Liquid (calculate Subcooling) Freon™ 507 refrigerant is an azeotropic mixture of R-125 and R-143a with zero ozone depletion potential (ODP). It is a safe, effective alternative to some chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants, including R-502. This hydrofluorocarbon (HFC) has similar qualities to R-502 and performs well in commercial ... A Versatile Replacement for Common R-12 Service Blends. Freon™ MO49Plus (R-437A) refrigerant was created as a hydrofluorocarbon (HFC) retrofit for service blends like R-101A, R-401B, and R-409A that contain hydrochlorofluorocarbon (HCFC) components. Freon™ MO49Plus provides a quick, cost-effective way to retrofit existing R-12 and R-500 ... Chart Review –Tip #3 • Reviewing the whole chart quickly –HUGE TIMESAVER #1 •MUCH, MUCH faster that using Clinical Notes display –Adjusting your view using PowerNote display –In PowerNote tab, change display to Only, then Note Type –This loads the whole chart in an organized hierarchy •: 2 , “ A”PJ Trailers is known for building premium gooseneck trailers for the hotshot industry. Hot shot truckers have increased needs for reliability, durability, comfort, and versatility. We created a guide for customers designing their next hot shot trailer that outlines the most popular specifications & options.P°.ressure control settings assume a suction line pressure loss equivalent to 2 F CARRYING CAPACITY OF REFRIGERATION LINES Tons of Refrigeration - 200 Feet Equivalent Pipe Length TYPE L COPPER TUBE O.D. Inches REFRIGERANT IRON PIPE SIZE Inches SCHEDULE REFRIGERANT 2a2 173 44)A/ 50 17 ( m onia L q u id Line S ct on 2° .0 F0Evap 2° .F0Evap ...

Freon Hot Shot™ 2 can be used in most applications to retrofit systems currently using R-12 or R-12 blends, including: How many ounces are in a can of Hot Shot? Hot Shot® Replaces R12, R134a, R401A, R401B, R409A, R416A, R420A, & R500, 28 oz. (1) 28 oz. Can of Hot-Shot R-414B . What is hot shot® R-12? Hot Shot® almost exactly duplicates the ... . 180 99

hot shot 2 p t chart

Freon™ HCFC refrigerants are available for servicing existing equipment in residential and commercial air conditioning and for medium- and low-temperature refrigeration applications. Freon™ 22 (R-22) Refrigerant. Freon™ 123 (R-123) Refrigerant. Freon™ 124 (R-124) Refrigerant. Freon™ MP39 (R-401A) Refrigerant.Manufacturers of refrigerants, controls, and other suppliers distribute hundreds of thousands of pressure-temperature charts to the trade every year. It woul...Use Hot Shot 2 P/T chart on reverse side. If additional Hot Shot 2 needs to be added, do so in 5% increments and DO NOT exceed 115% of the original charge of R-12. If system perfor FRIGERANTS-Conversion Recommendations And Procedures mance is inadequate, call ICOR for support at 800-497-6805. It facilitates easy retrofitting in which the technician simply recovers the R-22, replaces critical seals, charges the Freon™ MO99™ refrigerant, and monitors for leaks. Converting to Freon™ MO99™ also: Minimizes time needed for adjustments and subsequent service calls. Doesn't require an expansion valve or line set changes.the week’s most popular current songs across all genres, ranked by streaming activity from digital music sources tracked by luminate, radio airplay audience impressions as measured by luminate ... Use Hot Shot 2 P/T chart on reverse side. If additional Hot Shot 2 needs to be added, do so in 5% increments and DO NOT exceed 115% of the original charge of R-12. If system perfor-mance is inadequate, call ICOR for support at 800-497-6805. 9) PROPERLY LABEL SYSTEM: Avoid mixing refrigerants by properly labeling your system. For Hot Shot 2 ...PJ Trailers is known for building premium gooseneck trailers for the hotshot industry. Hot shot truckers have increased needs for reliability, durability, comfort, and versatility. We created a guide for customers designing their next hot shot trailer that outlines the most popular specifications & options.Make your job easier with our handy refrigerant pressure temperature HVAC app with R-414B included.PJ Trailers is known for building premium gooseneck trailers for the hotshot industry. Hot shot truckers have increased needs for reliability, durability, comfort, and versatility. We created a guide for customers designing their next hot shot trailer that outlines the most popular specifications & options. Chart Review –Tip #3 • Reviewing the whole chart quickly –HUGE TIMESAVER #1 •MUCH, MUCH faster that using Clinical Notes display –Adjusting your view using PowerNote display –In PowerNote tab, change display to Only, then Note Type –This loads the whole chart in an organized hierarchy •: 2 , “ A” Chart Review –Tip #3 • Reviewing the whole chart quickly –HUGE TIMESAVER #1 •MUCH, MUCH faster that using Clinical Notes display –Adjusting your view using PowerNote display –In PowerNote tab, change display to Only, then Note Type –This loads the whole chart in an organized hierarchy •: 2 , “ A”The P/T app displays a pressure or temperature based on the information a user inputs. For refrigerant blends, both the saturated vapor and liquid values are provided. The app uses input from the field service contractor to quickly calculate an operating system's superheat and sub-cooling, and to facilitate quick, accurate refrigeration or AC ...vapor temperature chart bg-4/14-2.5m. vapor temperature chart. r409a temp. liquid vapor. ... 135 57.2 317 365 329 507 140 60.0 337 389 353 539 145 62.8 359 - - 573 ...Freon™ 409A is a nonflammable hydrochlorofluorocarbon (HCFC) based refrigerant. It works with existing MO in many unitary and close-coupled systems, and requires 10-25% less refrigerant after retrofit. One compressor oil change to AB typically removes 50-80% of the existing MO to satisfy compressor OEM recommendations and requirements..