Lincoln sp 125 plus problems - It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...

 
Welding Equipment. Lincoln SP-125 Plus Welder. Machine has not been used in 3 years. Worked when removed from service. buyer responsible to provide help to remove it. no loading dock. Request appointment at asset location to view previous to bidding. Visit site and verify condition before bidding.. Ghbddr

Lincoln ElectricThis item, Lincoln SP-125 Plus Mig Welder, is part of the auction: Town of Hamburg Hwy, NY #14317. Lincoln SP-125 Plus wire feed problem 11-01-2008, 06:59 PM. A good friend of mine was given an old SP-125 that wasn’t quite working right. He replaced the gun, but now that I’m back I’ve checked it out and here’s the issue.Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...Opinions on 305G Lincoln; Best engine Drive under 5000$ SP-125 Plus Amperage Question; Oil Fill on Perkins engine for Lincoln 300D; help..need parts for SA 200; Wire burning before touching metal; SP 250 stutter; SA-200 Engine Frozen; Invertec Questions; Newbie here with a dumb question; Power Mig 180C pricing? Brand new Lincoln Pro 180 for ...Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantYou need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantDrive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 131 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.I had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderIf you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 Plus1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...Contact us by phone at 888-935-3877. Service & Distributor Locator. Print & Pdf Publications: REQUEST LITERATURE. COUNTERTOP PARTS GUIDE. (20 mb PDF) service navigator: video tips.Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)Rick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant02-04-2010 #1 Guard Solderer Join Date Feb 2010 Posts 4 Post Thanks / Like SP125 plus problems? Hello, I've had this for years w/gas bottle, and loved it so far! A few days ago trying to weld-up a snow blade for a 4-wheeler, It did fine for about 10 minutes, about 3-4 ins. of bead at a time, then quit putting anything out.Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Lincoln Electric is one of the world's largest manufacturers of industrial welding supplies, and WeldingMart is the largest online Lincoln welder parts dealer. We also carry a selection of parts from Miller Electric. Whether you're repairing an older welder or upgrading a new one, our high-quality welder parts and service will help make it happen.Premium quality 100Amp replacement MIG gun stinger torch, 10-foot (3m) cable, fully compatible with Lincoln Magnum 100L (K530-5) Usually Lincoln Magnum 100L (K530-5) MIG gun can be found on SP-85, SP-100, SP-100I, SP-100T, SP-125 Plus, SP-130T, SP-135 Plus, SP-140I, SP-155, SP-170, SP-170I, SP-170T, SP-175 Plus, SP-175T, Handy MIG 170I, MIG Pak 10, MIG Pak 15, Pro 100, Pro 155, Pro-Core 100 ...I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.Your #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.I have a Lincoln 135 Pro that I use all the time for sheetmetal. Works great, on the smaller stuff no problem. If you have the power, and the dough, go bigger, but if you have a 1927 house like me, with 120 wiring, its a good machine. When I upgrade my power, I will get a bigger machine for heavier stuff. flatheadhero, Mar 19, 2007.It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.Rick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.I bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.Home › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Nov 25, 2011 · Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool. I bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.Rick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.Ideal replacement for Lincoln Magnum 100L (K530-6). Usually, Lincoln Magnum 100L (K530-6) MIG gun can be found on SP-140T/180T, MIG-Pak 140/180, ProMIG 140/180, Weld-Pak 125HD/140HD/180HD, Power MIG 140C/180C and EasyCore 140/180, etc. welders. Use standard front consumables 21 series nozzle, 11 series tip and xx-40-15 liner.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantIf you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusIt started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.I have a Lincoln 135 Pro that I use all the time for sheetmetal. Works great, on the smaller stuff no problem. If you have the power, and the dough, go bigger, but if you have a 1927 house like me, with 120 wiring, its a good machine. When I upgrade my power, I will get a bigger machine for heavier stuff. flatheadhero, Mar 19, 2007.Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderQuality of work comes before profit! Old Fashion "Customer is always right policy". 1 year warranty. Fair Estimates on all Lincoln units. Low Prices. To have your Lincoln unit repaired/tested call 1- (336)-969-0110. Make. Part Number. Model Number.LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. Ideal replacement for Lincoln Magnum 100L (K530-6). Usually, Lincoln Magnum 100L (K530-6) MIG gun can be found on SP-140T/180T, MIG-Pak 140/180, ProMIG 140/180, Weld-Pak 125HD/140HD/180HD, Power MIG 140C/180C and EasyCore 140/180, etc. welders. Use standard front consumables 21 series nozzle, 11 series tip and xx-40-15 liner.This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.

I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro.... Big titty

lincoln sp 125 plus problems

PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.Lincoln Powermig 255. $2,200. Mount Vernon Triumph 2 & 4 Post Lifts, Low Price, Free Shipping, No Tax!!! $115. 0% 12 month Financing!!! Call or Text (866)774-7743If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,Welding Equipment. Lincoln SP-125 Plus Welder. Machine has not been used in 3 years. Worked when removed from service. buyer responsible to provide help to remove it. no loading dock. Request appointment at asset location to view previous to bidding. Visit site and verify condition before bidding.Welding Equipment; Cutting Equipment; Gear & Tools; Accessories; Welding Wire, Flux & Rods; Guns & Torches; Automated Welding & Cutting Systems; Training Equipment for EducatorsHome › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro...1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...Premium quality 100Amp replacement MIG gun stinger torch, 10-foot (3m) cable, fully compatible with Lincoln Magnum 100L (K530-5) Usually Lincoln Magnum 100L (K530-5) MIG gun can be found on SP-85, SP-100, SP-100I, SP-100T, SP-125 Plus, SP-130T, SP-135 Plus, SP-140I, SP-155, SP-170, SP-170I, SP-170T, SP-175 Plus, SP-175T, Handy MIG 170I, MIG Pak 10, MIG Pak 15, Pro 100, Pro 155, Pro-Core 100 ...926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,You need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power..

Popular Topics